#26 Differences in Rs and Bo: PVT experiment versus Black Oil Table

Black oil properties such as Bo and Rs relates reservoir fluid volumes to surface oil and gas volumes. Bo is the ratio of the oil volume at reservoir conditions to the oil volume at standard conditions (std):

Rs is the ratio of total gas volume in solution to the oil volume at standard conditions:

Bo and Rs values depend on the separation process taking place when the oil is taken from reservoir pressure and temperature down to standard conditions.

Bo from a Differential Liberation Experiment (sometimes called Bod)

To get insight into the compositional changes during natural depletion for an oil, it is common to carry out a Differential Liberation experiment (DLE) in a PVT lab. This experiment provides oil properties such as Bo (formation volume factor) and Rs (solution gas-oil ratio) at different pressures. However, these experimental Bo and Rs values are based on separations taking place at reservoir temperature in the PVT cell.

The actual fluid produced from the reservoir does not follow this separation path at reservoir temperature, instead the produced fluid from the reservoir enters a surface separation process before reaching standard conditions. Therefore, the Bo and Rs values from a differential liberation experiment cannot be used directly as input for a black oil reservoir simulation.

Bo for reservoir Black Oil simulation

Black Oil Tables (BOT) are used in reservoir simulators to represent the PVT behavior of the reservoir fluid as it is produced from the reservoir to standard conditions pressure and temperature through a surface separation process. The oil section of a BOT includes Bo and Rs values at different pressures. In PVTsim an Equation of State model is used to calculate BOT properties by simulating

  1. The compositional changes with pressure in the reservoir, which for an oil can be approximated by simulating a Differential Liberation experiment. The result is the composition of the produced reservoir fluid at different pressures.
  2. The surface separation process for the produced reservoir fluid.

The Bo and Rs values in a BOT for reservoir simulation are therefore different from those measured in the Differential Liberation experiment (as illustrated in Figure 1).

Figure 1 Black Oil table properties compared with properties obtained from a Differential Liberation Experiment.

Figure 2 illustrates the different separation paths taken in the Differential Liberation experiment compared to the BOT. When generating a Black Oil Table, the PVT experiment, e.g. DLE, is simulated to get the oil composition at each pressure stage, which is then used for simulating the properties Bo and Rs based on the surface separation process. The standard oil volume, , and standard gas volume, , are calculated as if a sample of oil with that composition is transferred from a PVT cell and taken through a separation process. As illustrated in Figure 2, the oil volume , is different for each pressure stage.

Figure 2 Left: Path bringing an oil to standard conditions in a Differential Liberation Experiment. Right: Paths bringing an oil to standard conditions when simulating a Differential Liberation Experiment for calculating Black Oil Table properties based on a surface Separation Process.

Figure 1 shows that the Bo and Rs values at each pressure stage in a Differential Liberation experiment are larger than the corresponding values in a BO table. The difference is more pronounced at the higher pressures. The main reason for the difference is the standard oil volume, , resulting from the experiment being smaller than the standard oil volumes calculated when generating a table. The separations in the PVT cell take place at reservoir temperature and in multiple pressure stages typically resulting in a larger fraction of mid-range hydrocarbon components evaporating. This leads to a reduced liquid volume and increased gas volume.

Since the separation into gas and oil takes place at different conditions and in a different number of stages for a reservoir fluid in a DLE experiment, when compared to an oil in a Black Oil Table, it follows that the standard volumes are different, so even if the pressure stages in a Differential Liberation Experiment, and a Black Oil  Table are the same, Bo and Rs will be different.